Specifications Table for FTXM-N / 3MXM-A

FTXM20N2V1B / FTXM20N2V1B / 3MXM40A2V1B FTXM25N2V1B / FTXM25N2V1B / 3MXM52A2V1B FTXM20N2V1B / FTXM20N2V1B / FTXM25N2V1B / 3MXM68A2V1B FTXM20N2V1B / FTXM25N2V1B / FTXM25N2V1B / 3MXM68A2V1B FTXM20N2V1B / FTXM50N2V1B / 3MXM68A2V1B FTXM25N2V1B / FTXM42N2V1B / 3MXM68A2V1B FTXM35N2V1B / FTXM35N2V1B / 3MXM68A2V1B
Cooling capacity Nom. kW 4.00 5.00 6.5 6.8 6.8 6.7 6.8
Heating capacity Nom. kW 4.60 6.80 8.20 8.60 8.60 8.30 8.60
Nominal efficiency EER   4.76 4.85 4.01 3.85 3.59 3.74 3.94
  COP   4.73 4.45 4.49 4.38 3.82 3.95 3.81
  Annual energy consumption kWh 420 515 810 883 947 896 863
  Energy labeling Directive Cooling   A A A A A A A
    Heating   A A A A A A A
Space cooling Energy efficiency class   A+++ A+++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 4.00 5.00 6.50 6.80 6.80 6.70 6.80
  SEER   8.53 8.59 7.76 7.71 6.75 6.94 6.97
  Annual energy consumption kWh/a 164 204 294 309 352 338 342
Space heating (Average climate) Energy efficiency class   A+ A+ A+ A+ A A A+
  Capacity Pdesign kW 4.80 4.80 5.30 5.30 4.50 4.30 4.80
  SCOP/A   4.25 4.38 4.09 4.10 3.90 3.86 4.00
  Pdh Heating capacity at -10° kW 3.60 3.90     3.55 3.41 3.73
  Annual energy consumption kWh/a 1582 1533 1814 1807 1612 1559 1680
Energy Efficiency Range A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data