Specifications Table for FTXM-M / RXM-M

FTXM20M2V1B / RXM20M2V1B FTXM25M2V1B / RXM25M2V1B FTXM35M2V1B / RXM35M2V1B FTXM42M2V1B / RXM42M2V1B FTXM42M2V1B / RXM42MV1B FTXM50M2V1B / RXM50M2V1B FTXM50M2V1B / RXM50MV1B FTXM60M2V1B / RXM60M2V1B FTXM71M2V1B / RXM71M2V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.70 1.7 1.70 1.7 1.9 2.30
  Max. kW 2.6 3.2 4.0 5.00 5.0 5.30 5.3 6.7 8.50
  Nom. kW 2.0 2.5 3.40 4.20 4.2 5.00 5.00 6.00 7.10
Space cooling SEER   8.53 8.52 8.51 7.50 7.50 7.33 7.33 6.90 6.11
  Annual energy consumption kWh/a 83 103 140 196 196 239 239 304 407
  Capacity Pdesign kW 2.00 2.50 3.40 4.20 4.20 5.00 5.00 6.00 7.10
  Energy efficiency class   A+++ A+++ A+++ A++ A++ A++ A++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 2.30 2.40 2.50 4.00 4.00 4.60 4.60 4.60 6.20
  SCOP/A   5.10 5.10 5.10 4.60 4.60 4.60 4.60 4.30 3.81
  Energy efficiency class   A+++ A+++ A+++ A++ A++ A++ A++ A+ A
  Pdh Heating capacity at -10° kW 2.24 2.3 2.35 3.68 3.68 4.09 4.09
  Annual energy consumption kWh/a 632 659 686 1,216 1,216 1,400 1,400 1,496 2,276
Nominal efficiency Annual energy consumption kWh 219 278 421   560   679 885
  EER   4.57 4.50 4.23 3.75 3.75 3.68 3.68 3.39 3.03
  COP   5.00 5.00 4.40 4.12 4.12 4.00 4.00 3.61 3.19
  Energy labeling Directive Cooling   A A A A A A A A B
    Heating   A A A A A A A A D
Heating capacity Nom. kW 2.50 2.8 4.00 5.40 5.40 5.80 5.8 7.00 8.20
  Min. kW 1.3 1.3 1.4 1.70 1.7 1.70 1.7 1.7 2.30
  Max. kW 3.5 4.70 5.2 6.00 6.0 6.50 6.5 8.0 10.20
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - See separate drawing for electrical data (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - See separate drawing for electrical data (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
        (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.   (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.     (3) - See separate drawing for electrical data