Specifications Table for FTXM-M / RXM-M9

FTXM20M2V1B / RXM20M3V1B9 FTXM25M2V1B / RXM25M3V1B9 FTXM35M2V1B / RXM35M3V1B9 FTXM42M2V1B / RXM42M3V1B9 FTXM50M2V1B / RXM50M3V1B9 FTXM60M2V1B / RXM60M3V1B9
Cooling capacity Min. kW 1.3 1.3 1.4 1.70 1.70 1.90
  Nom. kW 2.0 2.5 3.4 4.20 5.00 6.00
  Max. kW 2.6 3.2 4.0 5.00 5.30 6.70
Heating capacity Min. kW 1.30 1.30 1.40 1.70 1.70 1.70
  Nom. kW 2.50 2.80 4.00 5.40 5.80 7.00
  Max. kW 3.50 4.70 5.20 6.00 6.50 8.00
Nominal efficiency Annual energy consumption kWh 220 280 400      
  COP   5.00 5.00 4.04 4.12 4.00 3.61
  EER   4.57 4.50 4.23 3.75 3.68 3.39
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Annual energy consumption kWh/a 83 103 140 196 239 304
  Energy efficiency class   A+++ A+++ A+++ A++ A++ A++
  Capacity Pdesign kW 2.00 2.50 3.40 4.20 5.00 6.00
  SEER   8.53 8.52 8.51 7.50 7.33 6.90
Space heating (Average climate) Annual energy consumption kWh/a 632 659 686 1,216 1,400 1,496
  Capacity Pdesign kW 2.30 2.40 2.50 4.00 4.60 4.60
  Energy efficiency class   A+++ A+++ A+++ A++ A++ A+
  Pdh Heating capacity at -10° kW 2.24 2.30 2.35 3.68 4.09  
  SCOP/A   5.10 5.10 5.10 4.60 4.60 4.30
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.