Specifications Table for FHA-A(9) / RZQG-L9V1

FHA71AVEB9 / RZQG71L9V1B FHA100AVEB / RZQG71L9V1B FHA71AVEB99 / RZQG71L9V1B FHA100AVEB9 / RZQG71L9V1B FHA140AVEB / RZQG100L9V1B FHA100AVEB / RZQG100L9V1B FHA100AVEB9 / RZQG100L9V1B FHA140AVEB9 / RZQG100L9V1B FHA125AVEB / RZQG125L9V1B FHA140AVEB / RZQG125L9V1B FHA125AVEB9 / RZQG125L9V1B FHA140AVEB9 / RZQG125L9V1B FHA140AVEB / RZQG140L9V1B FHA140AVEB9 / RZQG140L9V1B
Cooling capacity Nom. kW 6.80 6.80 6.80 6.80 9.50 9.50 9.50 9.50 12.00 12.00 12.00 12.00 13.40 13.40
Heating capacity Nom. kW 7.50   7.50     10.80 10.80   13.50   13.50   15.50 15.50
Nominal efficiency EER   3.82 3.82 3.82 3.82 4.13 4.13 4.13 4.13 3.52 3.52 3.52 3.52 2.92 2.92
  COP   4.13   4.13     4.15 4.15   3.89   3.89   3.63 3.63
  Annual energy consumption kWh 890   890     1,150 1,150   1,705   1,705      
  Energy labeling Directive Cooling   A   A     A A   A   A      
    Heating   A   A     A A   A   A      
Space cooling Energy efficiency class   A++ A++ A++ A++ A++ A++ A++ A++ A+ A+ A+ A+    
  Capacity Pdesign kW 6.80 6.80 6.80 6.80 9.50 9.50 9.50 9.50 12.00 12.00 12.00 12.00 13.40 13.40
  SEER   6.86 6.86 6.86 6.86 6.11 6.11 6.11 6.11 6.01 6.01 6.01 6.01 6.22 6.22
  ηs,c %                         245.96 245.96
  Annual energy consumption kWh/a 347 347 347 347 545 545 545 545 699 699 699 699 1,292 1,292
Space heating (Average climate) Energy efficiency class   A+ A+ A+ A+ A++ A++ A++ A++ A+ A+ A+ A+    
  Capacity Pdesign kW 7.60 7.60 7.60 7.60 11.30 11.30 11.30 11.30 14.13 14.13 14.13 14.13 11.61 11.61
  SCOP/A   4.32 4.32 4.32 4.32 4.61 4.61 4.61 4.61 4.23 4.23 4.23 4.23 4.22 4.22
  ηs,h %                         165.87 165.87
  Annual energy consumption kWh/a 2,463 2,463 2,463 2,463 3,432 3,432 3,432 3,432 4,677 4,677 4,677 4,677 3,851 3,851
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - See separate drawing for operation range (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - See separate drawing for operation range (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - See separate drawing for operation range (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - See separate drawing for operation range (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - See separate drawing for electrical data (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - See separate drawing for electrical data (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - See separate drawing for electrical data (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - See separate drawing for electrical data (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range   (3) - See separate drawing for operation range     (3) - See separate drawing for operation range (3) - See separate drawing for operation range   (3) - See separate drawing for operation range   (3) - See separate drawing for operation range   (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data     (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data