FBA100A2VEB / RZAG71M7Y1B |
FBA140A2VEB / RZAG100M7Y1B |
FBA125A2VEB / RZAG125M7Y1B |
FBA140A2VEB / RZAG140M7Y1B |
FBA71A2VEB9 / RZAG71M7Y1B (Archived) |
FBA100A2VEB / RZAG100M7Y1B (Archived) |
Cooling capacity |
Nom. |
kW |
6.80 (1) |
9.50 (1) |
12.1 (1) |
13.4 (1) |
6.80 (1) |
9.50 (1) |
Heating capacity |
Nom. |
kW |
7.50 (2) |
10.8 (2) |
13.5 (2) |
15.5 (2) |
7.50 (2) |
10.8 (2) |
Space cooling |
Energy efficiency class |
A+ |
A++ |
|
|
A++ |
A++ |
|
Capacity |
Pdesign |
kW |
6.80 |
9.50 |
12.1 |
13.4 |
6.80 |
9.50 |
|
SEER |
5.81 |
6.39 |
6.19 |
6.42 |
6.22 |
6.47 |
|
Annual energy consumption |
kWh/a |
410 |
520 |
1,173 |
1,252 |
382 |
514 |
Space heating (Average climate) |
Energy efficiency class |
A+ |
A+ |
|
|
A+ |
A+ |
|
Capacity |
Pdesign |
kW |
4.70 |
7.80 |
9.52 |
9.52 |
4.70 |
7.80 |
|
SCOP/A |
4.06 |
4.20 |
4.12 |
4.11 |
4.20 |
4.36 |
|
Annual energy consumption |
kWh/a |
1,621 |
2,600 |
3,235 |
3,243 |
1,566 |
2,505 |
Notes |
(1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] |
(1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
|
|
|
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
|
|
|
(4) - See separate drawing for electrical data |
(4) - See separate drawing for electrical data |
(4) - See separate drawing for electrical data |