Specifications Table for ATXM-M / ARXM-N9

ATXM25M2V1B / ARXM25N5V1B9 ATXM25M2V1B / ARXM25N2V1B9 ATXM35M2V1B / ARXM35N2V1B9 ATXM35M2V1B / ARXM35N5V1B9 ATXM50N2V1B / ARXM50N2V1B9 ATXM50M2V1B / ARXM50N2V1B9
Cooling capacity Min. kW 1.3 1.3 1.4 1.4 1.70 1.70
  Nom. kW 2.5 2.5 3.4 3.4 5.00 5.00
  Max. kW 3.2 3.2 4.0 4.0 6.00 5.30
Heating capacity Min. kW 1.30 1.30 1.40 1.40 1.70 1.70
  Nom. kW 2.80 2.80 4.00 4.00 5.80 5.80
  Max. kW 4.70 4.70 5.20 5.20 7.70 6.50
Nominal efficiency Annual energy consumption kWh 285 285 415 415 725 (0.000)  
  COP   5.00 5.00 4.04 4.04 3.79 3.79
  EER   4.39 4.39 4.09 4.09 3.45 3.45
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Annual energy consumption kWh/a 103 103 140 140   239
  Energy efficiency class   A+++ A+++ A+++ A+++   A++
  Capacity Pdesign kW 2.50 2.50 3.40 3.40   5.00
  SEER   8.50 8.50 8.50 8.50   7.31
Space heating (Average climate) Annual energy consumption kWh/a 659 659 686 686   1,400
  Capacity Pdesign kW 2.40 2.40 2.50 2.50   4.60
  Energy efficiency class   A+++ A+++ A+++ A+++   A++
  SCOP/A   5.10 5.10 5.10 5.10   4.60
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for operation range (1) - See separate drawing for electrical data
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - See separate drawing for electrical data (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
          (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.