FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE
Cooling capacity Sensible capacity Nom. kW 2.4 2.7 3.2 5.1
  Latent capacity Nom. kW 0.4 0.9 1.3 2.0
  Total capacity Nom. kW 2.8 (1) 3.6 (1) 4.5 (1) 7.10 (1)
Heating capacity Total capacity Nom. kW 3.2 (2) 4.0 (2) 5.0 (2) 8.00 (2)
Power input - 50Hz Cooling Nom. kW 0.066 0.066 0.076 0.105
  Heating Nom. kW 0.046 0.046 0.056 0.085
Power input - 60Hz Cooling Nom. kW 0.069 0.069 0.092 0.120
  Heating Nom. kW 0.049 0.049 0.072 0.100
Dimensions Unit Height mm 215 215 215 215
    Width mm 1,110 1,110 1,110 1,310
    Depth mm 710 710 710 710
Weight Unit kg 31 31 31 34
Casing Material   Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate
Heat exchanger Rows Quantity   2 2 2 3
  Fin pitch mm 1.75 1.75 1.75 1.75
  Face area 0.180 0.180 0.180 0.226
  Stages Quantity   11 11 11 11
  Type   Cross fin coil Cross fin coil Cross fin coil Cross fin coil
Fan Type   Sirocco fan Sirocco fan Sirocco fan Sirocco fan
  Quantity   1 1 1 1
  Air flow rate - 50Hz Cooling High m³/min 11 11 13 18
      Low m³/min 9 9 10 15
  Air flow rate - 60Hz Cooling High m³/min 11 11 13 18
      Low m³/min 8.5 8.5 10 13
Sound pressure level Cooling High dBA 38.0 38.0 40.0 42.0
    Low dBA 33.0 33.0 34.0 37.0
Fan motor Quantity   1 1 1 1
  Model   3D12H1AN1V1 3D12H1AN1V1 3D12H1AP1V1 4D12H1AJ1V1
  Drive   Direct drive Direct drive Direct drive Direct drive
  Output High W 15 15 20 45
Refrigerant Type   R-410A R-410A R-410A R-410A
  GWP   2,087.5 2,087.5 2,087.5 2,087.5
  Control   Electronic expansion valve Electronic expansion valve Electronic expansion valve Electronic expansion valve
Sound power level Cooling High dBA 54 54 56 58
    Low dBA 49 49 50 53
Piping connections Liquid Type   Flare connection Flare connection Flare connection Flare connection
    OD mm 6.35 6.35 6.35 9.52
  Gas Type   Flare connection Flare connection Flare connection Flare connection
    OD mm 12.7 12.7 12.7 15.9
  Drain   VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25)
  Heat insulation   Foamed Polyethylene Foamed Polyethylene Foamed Polyethylene Foamed Polyethylene
Decoration panel Model   BYK45FJW1 BYK45FJW1 BYK45FJW1 BYK71FJW1
  Colour   White White White White
  Dimensions Height mm 70 70 70 70
    Width mm 1,240 1,240 1,240 1,440
    Depth mm 800 800 800 800
  Weight kg 8.5 8.5 8.5 9.5
Air filter Type   Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance
Safety devices Item 01   Fuse Fuse Fuse Fuse
    02   Fan motor thermal fuse Fan motor thermal fuse Fan motor thermal fuse Fan motor thermal fuse
Control systems Infrared remote control   BRC4C61 BRC4C61 BRC4C61 BRC4C61
  Wired remote control   BRC1H519W/S/K, BRC1E53A, BRC1E53B, BRC1E53C, BRC1D52 BRC1H519W/S/K, BRC1E53A, BRC1E53B, BRC1E53C, BRC1D52 BRC1H519W/S/K, BRC1E53A, BRC1E53B, BRC1E53C, BRC1D52 BRC1H519W/S/K, BRC1E53A, BRC1E53B, BRC1E53C, BRC1D52
Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating
Power supply Name   VE VE VE VE
  Phase   1~ 1~ 1~ 1~
  Frequency Hz 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220
Current - 50Hz Minimum circuit amps (MCA) A 0.3 0.3 0.3 0.5
  Maximum fuse amps (MFA) A 15 15 15 15
  Full load amps (FLA) Total A 0.2 0.2 0.2 0.4
Current - 60Hz Minimum circuit amps (MCA) A 0.4 (0.000) 0.4 (0.000) 0.5 (0.000) 0.6 (0.000)
  Maximum fuse amps (MFA) A 15.0 (0.000) 15.0 (0.000) 15.0 (0.000) 15.0 (0.000)
  Full load amps (FLA) Total A 0.3 (0.000) 0.3 (0.000) 0.4 (0.000) 0.5 (0.000)
Voltage range Max. % 10 10 10 10
  Min. % -10 -10 -10 -10
Notes Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
  Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
  Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
  Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%.
  MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA
  MFA ≤ 4 x FLA MFA ≤ 4 x FLA MFA ≤ 4 x FLA MFA ≤ 4 x FLA
  Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A
  Select wire size based on the value of MCA Select wire size based on the value of MCA Select wire size based on the value of MCA Select wire size based on the value of MCA
  Use a circuit breaker instead of a fuse. Use a circuit breaker instead of a fuse. Use a circuit breaker instead of a fuse. Use a circuit breaker instead of a fuse.
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases