FVXS25FV1B / RXS25L3V1B FVXS35FV1B / RXS35L3V1B
Indoor unit FVXS25F FVXS35F
Outdoor unit RXS25L3 RXS35L3
Cooling capacity Min. kW 1.3 1.4
  Min. Btu/h 4,400 4,800
  Min. kcal/h 1,120 1,200
  Nom. kW 2.5 (2) 3.5 (2)
  Nom. Btu/h 8,500 (2) 11,900 (2)
  Nom. kcal/h 2,150 (2) 3,010 (2)
  Max. kW 3.0 3.8
  Max. Btu/h 10,200 13,000
  Max. kcal/h 2,580 3,270
Heating capacity Min. kW 1.3 1.4
  Min. Btu/h 4,400 4,800
  Min. kcal/h 1,120 1,200
  Nom. kW 3.4 (2) 4.5 (2)
  Nom. Btu/h 11,600 (2) 15,400 (2)
  Nom. kcal/h 2,920 (2) 3,870 (2)
  Max. kW 4.5 5.0
  Max. Btu/h 15,400 17,100
  Max. kcal/h 3,870 4,300
Power input Cooling Min. kW 0.300 0.300
    Nom. kW 0.606 (2) 1.060 (2)
    Max. kW 0.920 1.250
  Heating Min. kW 0.290 0.310
    Nom. kW 0.770 (2) 1.190 (2)
    Max. kW 1.390 1.880
Nominal efficiency EER   4.12 (1) 3.30 (1)
  COP   4.42 (1) 3.78 (1)
  Annual energy consumption kWh 303 530
  Energy labeling Directive Cooling   A A
    Heating   A A
Space cooling Capacity Pdesign kW 2.50 3.50
  Energy efficiency class   A+ A+
  SEER   5.74 5.60
  Annual energy consumption kWh/a 152 219
  A Condition (35°C - 27/19) Pdc kW 2.50 3.50
    EERd   4.12 3.30
    Power input kW 0.61 1.06
  B Condition (30°C - 27/19) Pdc kW 1.84 2.58
    EERd   6.56 5.26
    Power input kW 0.28 0.49
  C Condition (25°C - 27/19) Pdc kW 1.41 1.65
    EERd   9.09 7.94
    Power input kW 0.16 0.21
  D Condition (20°C - 27/19) Pdc kW 1.49 1.50
    EERd   11.41 11.01
    Power input kW 0.13 0.14
Space heating (Average climate) Capacity Pdesign kW 2.60 2.90
  Energy efficiency class   A+ A
  SCOP/A   4.56 3.93
  SCOPnet/A   4.63 3.98
  Annual energy consumption kWh/a 798 1,033
  Required back up heating cap at design conditions kW 0.37 0.50
  TOL Tol (temperature operating limit) °C -15 -15
    Pdh (declared heating cap) kW 2.09 2.12
    COPd (declared COP)   2.31 1.96
    Power input kW 0.90 1.08
  TBivalent Tbiv (bivalent temperature) °C -7 -7
    Pdh (declared heating cap) kW 2.30 2.57
    COPd (declared COP)   2.76 2.42
    Power input kW 0.83 1.06
  A Condition (-7°C) Pdh (declared heating cap) kW 2.30 2.57
    COPd (declared COP)   2.76 2.42
    Power input kW 0.83 1.06
  B Condition (2°C) Pdh (declared heating cap) kW 1.40 1.56
    COPd (declared COP)   4.80 4.11
    Power input kW 0.29 0.38
  C Condition (7°C) Pdh (declared heating cap) kW 1.08 1.02
    COPd (declared COP)   5.98 4.80
    Power input kW 0.18 0.21
  D Condition (12°C) Pdh (declared heating cap) kW 1.26 1.19
    COPd (declared COP)   7.16 6.35
    Power input kW 0.18 0.19
Power consumption in other than active mode Crankcase heater mode PCK W 0.0 0.0
  Off mode POFF W 14.0 14.0
  Standby mode Cooling PSB W 14.0 14.0
Pto (Thermostat off) W 40.0 40.0
Cooling Cdc (Degradation cooling)   0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25
Cooling function included Yes Yes
Heating function included Yes Yes
Average climate included Yes Yes
Cold season included No No
Warm season included No No
Ecolabel logo No No
Moisture removal Cooling l/h 1.2 1.9
  Heating l/h 10.0  
Piping connections Drain OD mm 20.0 20.0
  Gas OD mm 9.5 9.5
  Heat insulation   Both liquid and gas pipes Both liquid and gas pipes
  Liquid OD mm 6.35 6.35
Current Nominal running current (RLA) - 50Hz Cooling A 3.72 (3), 3.51 (4), 3.40 (5) 5.09 (3), 4.88 (4), 4.68 (5)
    Heating A 4.50 (3), 4.30 (4), 4.10 (5) 5.90 (3), 5.60 (4), 5.40 (5)
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (3) - 220V (3) - 220V
  (4) - 230V (4) - 230V
  (5) - 240V (5) - 240V