Specifications Table for FVXS-F / RXL-J

FVXS25FV1B / RXL25J2V1B FVXS35FV1B / RXL35J2V1B FVXS35FV1B / RXL35J3V1B FVXS50FV1B / RXL50J2V1B FVXS50FV1B / RXL50J3V1B
Cooling capacity Min. kW 1.3 1.4 1.4 1.4 1.4
  Nom. kW 2.5 (3) 3.5 (3) 3.5 (2) 5.0 (2) 5.0 (2)
  Max. kW 3.0 3.8 3.8 5.6 5.6
Heating capacity Min. kW 1.3 1.4 1.4 1.4 1.4
  Nom. kW 3.4 (4) 4.5 (4) 4.5 (3) 5.8 (3) 5.8 (3)
  Max. kW 4.5 5.0 5.0 8.1 8.1
Nominal efficiency EER   4.39 4.30 3.43 (1) 3.23 (1) 3.23 (1)
  COP   3.43 3.69 3.69 (1) 3.63 (1) 3.63 (1)
  Annual energy consumption kWh 285 407 510 775 775
  Energy labeling Directive Cooling   A A A A A
    Heating   B A A A A
Space cooling Capacity Pdesign kW     3.50   5.00
  Energy efficiency class     B   A
  SEER     4.93   5.53
  Annual energy consumption kWh/a     248   317
Space heating (Average climate) Capacity Pdesign kW     2.90   4.80
  Energy efficiency class     A   A
  SCOP/A     3.77   3.59
  Annual energy consumption kWh/a     1,077   1,874
Piping connections Drain OD mm     20.0 20.0 20.0
  Gas OD mm 9.5 9.5 9.5 12.7 12.7
  Liquid OD mm 6.35 6.35 6.35 6.35 6.35
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - 220V (4) - 220V (4) - 220V
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - 230V (5) - 230V (5) - 230V
      (6) - 240V (6) - 240V (6) - 240V
      (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load