Specifications Table for FVXS-F / RXL-J

FVXS25FV1B / RXL25J2V1B FVXS35FV1B / RXL35J3V1B FVXS35FV1B / RXL35J2V1B FVXS50FV1B / RXL50J3V1B FVXS50FV1B / RXL50J2V1B
Poff (Off mode) W   20.0   20.0  
Cooling Psb (Standby mode cooling) W   20.0   20.0  
Eurovent Sound power level indoor Cooling Nom. dBA         60
  Sound power level outdoor Cooling Nom. dBA         62
Seasonal efficiency (according to EN14825) Cooling Pdesign kW   3.50   5.00  
    Annual energy consumption kWh   248   317  
    D Condition (20°C - 27/19) Pdc kW   1.80   2.23  
      power input kW   0.18   0.20  
    C Condition (25°C - 27/19) power input kW   0.22   0.30  
      Pdc kW   1.71   2.37  
    A Condition (35°C - 27/19) power input kW   1.07   1.47  
      Pdc kW   3.50   5.00  
    B Condition (30°C - 27/19) Pdc kW   2.58   3.69  
      power input kW   0.50   0.70  
  Heating (Average climate) Annual energy consumption kWh   1,077   1,874  
    Pdesign kW   2.90   4.80  
    Required back up heating cap at design conditions kW   0.57   0.87  
    TBivalent Pdh (declared heating cap) kW   2.57   4.25  
      Power input kW   1.18   2.16  
      Tbiv (bivalent temperature) °C   -7   -7  
    C Condition (7°C) Pdh (declared heating cap) kW   1.35   1.67  
      Power input kW   0.26   0.35  
    TOL Tol (temperature operating limit) °C   -25   -25  
      Pdh (declared heating cap) kW   1.13   2.36  
      Power input kW   1.09   2.34  
    A Condition (-7°C) Pdh (declared heating cap) kW   2.57   4.25  
      Power input kW   1.18   2.16  
    D Condition (12°C) Pdh (declared heating cap) kW   1.58   1.80  
      Power input kW   0.25   0.31  
    B Condition (2°C) Power input kW   0.37   0.69  
      Pdh (declared heating cap) kW   1.56   2.59  
Cooling capacity Nom. Btu/h   11,900 (2)   17,100 (2) 17,100 (2)
  Min. kW 1.3 1.4 1.4 1.4 1.4
  Nom. kcal/h   3,010 (2)   4,300 (2) 4,300 (2)
  Max. kW 3.0 3.8 3.8 5.6 5.6
  Min. kcal/h   1,200   1,200 1,200
  Min. Btu/h   4,800   4,800 4,800
  Nom. kW 2.5 (3) 3.5 (2) 3.5 (3) 5.0 (2) 5.0 (2)
  Max. Btu/h   13,000   18,100 18,100
  Max. kcal/h   3,270   4,820 4,820
Pck (Crankcase heater mode) W   0.0   0.0  
Nominal efficiency Annual energy consumption kWh 285 (0.000) 510 (0.000) 407 (0.000) 775 (0.000) 775 (0.000)
  Energy labeling Directive Heating A A A A A
  Nominal efficiency-=-Cop 4.39 3.43 (1) 4.30 3.23 (1) 3.23 (1)
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 12.7 12.7
  Drain OD mm   20.0   20.0 20.0
Heating capacity Min. Btu/h   4,800   4,800 4,800
  Nom. Btu/h   15,400 (3)   19,800 (3) 19,800 (3)
  Max. kcal/h   4,300   6,970 6,970
  Max. Btu/h   17,100   27,600 27,600
  Nom. kW 3.4 (4) 4.5 (3) 4.5 (4) 5.8 (3) 5.8 (3)
  Min. kW 1.3 1.4 1.4 1.4 1.4
  Nom. kcal/h   3,870 (3)   4,990 (3) 4,990 (3)
  Min. kcal/h   1,200   1,200 1,200
  Max. kW 4.5 5.0 5.0 8.1 8.1
Pto (Thermostat off) W   80.0   80.0  
Power input Cooling Min. kW   0.300   0.500 0.500
    Nom. kW 0.57 1.020 0.81 1.550 1.550 (2)
    Max. kW   1.250   2.000 2.000
  Heating Max. kW   1.880   2.600 2.600
    Min. kW   0.310   0.500 0.500
    Nom. kW 0.99 1.220 1.22 1.600 1.600 (3)
Current Nominal running current (RLA) - 50Hz Heating A   5.9 (4), 5.6 (5), 5.4 (6)   7.3 (4), 7.0 (5), 6.7 (6) 7.3 (4), 7.0 (5), 6.7 (6)
    Cooling A   4.9 (4), 4.7 (5), 4.5 (6)   7.2 (4), 6.8 (5), 6.6 (6) 7.2 (4), 6.8 (5), 6.6 (6)
Notes Energy label: scale from A (most efficient) to G (less efficient) EER/COP according to Eurovent 2012, for use outside EU only Energy label: scale from A (most efficient) to G (less efficient) EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) 220V Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) 220V 220V
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 230V Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 230V 230V
Cooling Cooling-=-Cooling cdc degradation cooling   0.25   0.25  
Seasonal efficiency (according to EN14825) Cooling Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class   4.93   5.53  
    D Condition (20°C - 27/19) Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd   9.83   10.90  
    C Condition (25°C - 27/19) Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd   7.73   7.96  
    A Condition (35°C - 27/19) Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd   3.27   3.40  
    B Condition (30°C - 27/19) Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd   5.21   5.29  
  Heating (Average climate) Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a   A   A  
    TBivalent Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop   2.17   1.97  
    C Condition (7°C) Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop   5.10   4.75  
    TOL Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop   1.04   1.01  
    A Condition (-7°C) Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop   2.17   1.97  
    D Condition (12°C) Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop   6.21   5.82  
    B Condition (2°C) Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop   4.18   3.77  
Heating Heating-=-Heating cdh degradation heating   0.25   0.25  
Piping connections Heat insulation   Both liquid and gas pipes   Both liquid and gas pipes Both liquid and gas pipes
Cold season included   Yes   Yes  
Notes   240V   240V 240V
    Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load