Specifications Table for FTXG-LS

FTXG25LV1BS FTXG50LV1BS FTXG20LV1BS (Archived) FTXG35LV1BS (Archived)
Power input Cooling Nom. kW 0.023 (1), 0.023 (2), 0.023 (3) 0.033 (1), 0.033 (2), 0.033 (3) 0.023 (1), 0.023 (2), 0.023 (3) 0.033 (1), 0.033 (2), 0.033 (3)
  Heating Nom. kW 0.033 (1), 0.033 (2), 0.033 (3) 0.043 (1), 0.043 (2), 0.043 (3) 0.031 (1), 0.031 (2), 0.031 (3) 0.042 (1), 0.042 (2), 0.042 (3)
Casing Colour   Silver Silver Silver Silver
Dimensions Unit Height mm 303 303 303 303
    Width mm 998 998 998 998
    Depth mm 212 212 212 212
Weight Unit kg 12.0 12.0 12.0 12.0
Sound power level Cooling dBA 54 60 54 59
  Heating dBA 56 60 56 59
Sound pressure level Cooling High dBA 38 46 38 45
    Medium dBA 32 40 32 34
    Low dBA 25 35 25 26
    Silent operation dBA 19 25 19 20
  Heating High dBA 41 47 40 45
    Medium dBA 34 41 34 37
    Low dBA 28 35 28 29
    Silent operation dBA 19 25 19 20
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35
  Gas OD mm 9.50 12.7 9.50 9.50
  Drain   18 18 18 18
Control systems Infrared remote control   ARC466A9 ARC466A9 ARC466A9 ARC466A9
Standard Accessories Installation manual 1 1 1 1
  Operation manual 1 1 1 1
  Wireless remote control 1 1 1 1
  Batteries 2 2 2 2
  Remote control holder 1 1 1 1
  Mounting plate 1 1 1 1
  Indoor unit fixing screws 2 2 2 2
  Titanium apatite deodorizing filter 2 2 2 2
  Screw cover 2 2 2 2
Power supply Name   V1 V1 V1 V1
  Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240
Notes (1) - 220V (1) - 220V (1) - 220V (1) - 220V
  (2) - 230V (2) - 230V (2) - 230V (2) - 230V
  (3) - 240V (3) - 240V (3) - 240V (3) - 240V
  (4) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (4) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (4) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (4) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.