FHA50AVEB9 / RXM50N2V1B
Indoor unit FHA50AVEB9
Outdoor unit RXM50N2V1B
Cooling capacity Nom. kW 5.00
  Nom. Btu/h 17,100
  Nom. kcal/h 4,299
Heating capacity Nom. kW 6.00
  Nom. Btu/h 20,500
  Nom. kcal/h 5,159
Power input Cooling Nom. kW 1.56
  Heating Nom. kW 1.79
Nominal efficiency EER   3.21
  COP   3.35
  Annual energy consumption kWh 779
  Energy labeling Directive Cooling   A
    Heating   A
Space cooling Capacity Pdesign kW 5.00
  Energy efficiency class   A+
  SEER   5.92
  Annual energy consumption kWh/a 295
  A Condition (35°C - 27/19) Pdc kW 5.00
    EERd   3.21
    Power input kW 1.56
  B Condition (30°C - 27/19) Pdc kW 3.69
    EERd   5.04
    Power input kW 0.73
  C Condition (25°C - 27/19) Pdc kW 2.37
    EERd   7.39
    Power input kW 0.32
  D Condition (20°C - 27/19) Pdc kW 2.31
    EERd   9.31
    Power input kW 0.25
Space heating (Average climate) Capacity Pdesign kW 4.35
  Energy efficiency class   A
  SCOP/A   3.86
  SCOPnet/A   3.88
  Pdh Heating capacity at -10° kW 3.85
  Annual energy consumption kWh/a 1,578
  Required back up heating cap at design conditions kW 0.50
  TOL Tol (temperature operating limit) °C -15
    Pdh (declared heating cap) kW 3.86
    COPd (declared COP)   1.97
    Power input kW 1.96
  TBivalent Tbiv (bivalent temperature) °C -7
    Pdh (declared heating cap) kW 3.85
    COPd (declared COP)   2.61
    Power input kW 1.48
  A Condition (-7°C) Pdh (declared heating cap) kW 3.85
    COPd (declared COP)   2.61
    Power input kW 1.48
  B Condition (2°C) Pdh (declared heating cap) kW 2.33
    COPd (declared COP)   3.95
    Power input kW 0.59
  C Condition (7°C) Pdh (declared heating cap) kW 1.54
    COPd (declared COP)   4.62
    Power input kW 0.33
  D Condition (12°C) Pdh (declared heating cap) kW 1.80
    COPd (declared COP)   5.65
    Power input kW 0.32
Space heating (Warm climate) Capacity Pdesignh kW 2.33
  Energy efficiency class   A+
  SCOP   4.56
  SCOPnet   4.64
  Annual energy consumption kWh/a 715
  Required back up heating cap at design conditions kW 0.00
  TOL Tol (temperature operating limit) °C -15
    Pdh (declared heating cap) kW 3.86
    COPd (declared COP)   1.97
    Power input kW 1.96
  TBivalent Tbiv (bivalent temperature) °C 2
    Pdh (declared heating cap) kW 2.33
    COPd (declared COP)   3.95
    Power input kW 0.59
  B Condition (2°C) Pdh (declared heating cap) kW 2.33
    COPd (declared COP)   3.95
    Power input kW 0.59
  C Condition (7°C) Pdh (declared heating cap) kW 1.54
    COPd (declared COP)   4.62
    Power input kW 0.33
  D Condition (12°C) Pdh (declared heating cap) kW 1.80
    COPd (declared COP)   5.65
    Power input kW 0.32
Power consumption in other than active mode Crankcase heater mode PCK W 0
  Off mode POFF W 6
  Standby mode Cooling PSB W 7
    Heating PSB W 6
  Thermostat-off mode PTO Cooling W 9
      Heating W 15
Cooling Cdc (Degradation cooling)   0.25
Heating Cdh (Degradation heating)   0.25
Cooling function included Yes
Heating function included Yes
Average climate included Yes
Cold season included No
Warm season included Yes
Eurovent Sound power level outdoor Cooling Nom. dBA 62
  Sound power level indoor Cooling Nom. dBA 54
  Piping length Cooling Measuring condition m 5.00
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data