FFQ25C2VEB / RXL25K3V1B FFQ35C2VEB / RXL35K2V1B FFQ50C2VEB / RXL50K2V1B
Poff (Off mode) W 15.0 14.0 15.0
Cooling Psb (Standby mode cooling) W 20.0 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 2.50 3.40 5.00
    Annual energy consumption kWh 167 210 307
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.25 5.66 5.70
    D Condition (20°C - 27/19) Pdc kW 2.17 1.87 2.32
      power input kW 0.22 0.18 0.22
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.96 10.61 10.41
    C Condition (25°C - 27/19) power input kW 0.25 0.21 0.31
      Pdc kW 2.03 1.78 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.02 8.39 7.72
    A Condition (35°C - 27/19) power input kW 0.56 0.93 1.57
      Pdc kW 2.50 3.40 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.45 3.66 3.18
    B Condition (30°C - 27/19) Pdc kW 1.95 2.51 3.68
      power input kW 0.29 0.42 0.71
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.68 5.99 5.20
  Heating (Average climate) Annual energy consumption kWh 807 1,209 1,331
    Pdesign kW 2.31 3.45 3.84
    Required back up heating cap at design conditions kW 0.28 0.62 0.33
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+ A A
    TBivalent Pdh (declared heating cap) kW 2.03 3.05 3.40
      Power input kW 1.46 1.02 1.47
      Tbiv (bivalent temperature) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 1.39 2.98 2.32
    C Condition (7°C) Pdh (declared heating cap) kW 1.11 1.48 1.40
      Power input kW 0.21 0.28 0.25
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.25 5.34 5.50
    TOL Tol (temperature operating limit) °C -15 -25 -25
      Pdh (declared heating cap) kW 2.02 1.71 4.06
      Power input kW 1.07 1.69 2.74
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.88 1.01 1.48
    A Condition (-7°C) Pdh (declared heating cap) kW 2.03 3.06 3.41
      Power input kW 1.46 1.02 1.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 1.39 2.99 2.31
    D Condition (12°C) Pdh (declared heating cap) kW 1.30 1.70 1.64
      Power input kW 0.20 0.27 0.23
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.42 6.38 6.99
    B Condition (2°C) Power input kW 0.28 0.48 0.51
      Pdh (declared heating cap) kW 1.24 1.86 2.08
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.37 3.84 4.06
Cooling capacity Nom. Btu/h   11,590 17,050
  Min. kW   1.4 1.4
  Nom. kcal/h   2,920 4,300
  Max. kW   4.0 5.3
  Min. kcal/h   1,200 1,200
  Min. Btu/h   4,770 4,770
  Nom. kW 2.50 3.40 5.00
  Max. Btu/h   13,640 18,070
  Max. kcal/h   3,440 4,560
Pck (Crankcase heater mode) W 0.0 0.0 0.0
Nominal efficiency Annual energy consumption kWh 280 (0.000) 460 (0.000) 780 (0.000)
  Energy labeling Directive Heating A A A
  Nominal efficiency-=-Cop 4.46 3.70 3.21
Heating Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Heating capacity Min. Btu/h   4,430 4,770
  Nom. Btu/h   14,320 19,780
  Max. kcal/h   4,380 5,330
  Max. Btu/h   17,390 21,140
  Nom. kW 3.20 4.20 5.80
  Min. kW   1.3 1.4
  Nom. kcal/h   3,610 4,990
  Min. kcal/h   1,120 1,200
  Max. kW   5.1 6.2
Pto (Thermostat off) W 40.0 40.0 40.0
Power input Cooling Min. kW   0.360 0.540
    Nom. kW 0.56 0.920 1.560
    Max. kW   1.470 2.030
  Heating Max. kW   1.650 2.170
    Min. kW   0.300 0.250
    Nom. kW 0.84 1.230 1.660
Cold season included Yes Yes Yes
Notes EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load