FCAG35AVEB FCAG50AVEB FCAG60AVEB FCAG71AVEB FCAG100AVEB FCAG125AVEB FCAG140AVEB
Cooling capacity Sensible capacity Nom. kW           8.71 8.68
  Latent capacity Nom. kW           3.39 4.72
  Total capacity Nom. kW           12.10 13.40
Heating capacity Total capacity Nom. kW           13.5 15.5
Power input - 50Hz Cooling Nom. kW           0.17 0.17
  Heating Nom. kW           0.17 0.17
Casing Material   Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate
Dimensions Unit Height mm 204 204 204 204 246 246 246
    Width mm 840 840 840 840 840 840 840
    Depth mm 840 840 840 840 840 840 840
  Packed unit Height mm 220 220 220 220 260 260 260
    Width mm 882 882 882 882 882 882 882
    Depth mm 882 882 882 882 882 882 882
Weight Unit kg 18 19 19 21 24 24 24
  Packed unit kg 20 21 21 23 26 26 26
Heat exchanger Inside length mm 2,134 2,134 2,134 2,090 2,090 2,090 2,090
  Outside length mm 2,181 2,181 2,181 2,184 2,184 2,184 2,184
  Rows Quantity   2 2 2 3 3 3 3
  Fin pitch mm 1.20 1.20 1.20 1.20 1.20 1.20 1.20
  Passes Quantity   4 6 6 12 14 14 14
  Face area 0.278 0.366 0.366 0.371 0.464 0.464 0.464
  Stages Quantity   9 12 12 12 15 15 15
  Empty tubeplate hole Quantity   0 0 0 0 0 0 0
  Tube type   Ø5 HI-XA Ø5 HI-XA Ø5 HI-XA Ø5 HI-XA Ø5 HI-XA Ø5 HI-XA Ø5 HI-XA
  Fin Type   Cross fin coil (multi slit fins and hi-XA tubes) Cross fin coil (multi slit fins and hi-XA tubes) Cross fin coil (multi slit fins and hi-XA tubes) Cross fin coil (multi slit fins and hi-XA tubes) Cross fin coil (multi slit fins and hi-XA tubes) Cross fin coil (multi slit fins and hi-XA tubes) Cross fin coil (multi slit fins and hi-XA tubes)
Fan Type   Turbo fan Turbo fan Turbo fan Turbo fan Turbo fan Turbo fan Turbo fan
  Quantity   1 1 1 1 1 1 1
  Air flow rate Cooling High m³/min 12.5 12.6 13.6 15.3 22.8 26.0 26.0
      High cfm 441 445 480 540 805 918 918
      Medium m³/min 10.6 (0.000) 10.7 (0.000) 11.2 (0.000) 12.5 17.6 (0.000) 19.2 (0.000) 19.2 (0.000)
      Medium cfm 374 378 396 441 622 678 678
      Low m³/min 8.7 8.7 8.7 9.3 12.4 12.4 12.4
      Low cfm 307 307 307 328 438 438 438
    Heating High m³/min 13.9 12.6 13.6 15.0 22.8 26.0 26.0
      High cfm 491 445 480 530 805 918 918
      Medium m³/min 11.6 (0.000) 10.7 (0.000) 11.2 (0.000) 12.1 17.6 (0.000) 19.2 (0.000) 19.2 (0.000)
      Medium cfm 410 378 396 427 622 678 678
      Low m³/min 9.3 8.7 8.7 9.1 12.4 12.4 12.4
      Low cfm 328 307 307 321 438 438 438
Fan motor Model   ARW5202DK ARW5202DK ARW5202DK ARW5202DK EHDS10CDK EHDS10CDK EHDS10CDK
  Speed Steps   3 3 3 3 3 3 3
  Output High W 48 48 48 48 106 106 106
Sound power level Cooling dBA 49 49 51 51 54 58 58
  Heating dBA 49 49 51 51 54 58 58
Sound pressure level Cooling High dBA 31 31 33 35 37 41 41
    Medium dBA 29 (0.000) 29 (0.000) 31 (0.000) 31 33 (0.000) 35 (0.000) 35 (0.000)
    Low dBA 27 27 28 28 29 29 29
  Heating High dBA 31 31 33 33 37 41 41
    Medium dBA 29 29 31 31 33 35 35
    Low dBA 27 27 28 28 29 29 29
Refrigerant Type   R-32, R-410A R-32, R-410A R-32, R-410A R-32, R-410A R-32, R-410A R-32, R-410A R-32, R-410A
Piping connections Sound absorbing insulation   Foamed polyurethane Foamed polyurethane Foamed polyurethane Foamed polyurethane Foamed polyurethane Foamed polyurethane Foamed polyurethane
  Liquid Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm 6,35 6,35 6,35 9,52 9,52 9,52 9,52
  Gas Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm 9.52 12.70 12.70 15.90 15.90 15.90 15.90
  Drain   VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25)
  Heat insulation   Foamed polystyrene / Foamed polyethylene Foamed polystyrene / Foamed polyethylene Foamed polystyrene / Foamed polyethylene Foamed polystyrene / Foamed polyethylene Foamed polystyrene / Foamed polyethylene Foamed polystyrene / Foamed polyethylene Foamed polystyrene / Foamed polyethylene
Decoration panel Model   BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter BYCQ140D7GFW1 - auto cleaning panel with fine mesh filter
  Colour   Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)
  Dimensions Height mm 130 130 130 130 130 130 130
    Width mm 950 950 950 950 950 950 950
    Depth mm 950 950 950 950 950 950 950
  Weight kg 10.3 10.3 10.3 10.3 10.3 10.3 10.3
Decoration panel 2 Model   BYCQ140D7W1W - full white BYCQ140D7W1W - full white BYCQ140D7W1W - full white BYCQ140D7W1W - full white BYCQ140D7W1W - full white BYCQ140D7W1W - full white BYCQ140D7W1W - full white
  Colour   Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)
  Dimensions Height mm 50 50 50 50 50 50 50
    Width mm 950 950 950 950 950 950 950
    Depth mm 950 950 950 950 950 950 950
  Weight kg 5.4 5.4 5.4 5.4 5.4 5.4 5.4
Decoration panel 3 Model   BYCQ140D7GW1 - auto cleaning panel BYCQ140D7GW1 - auto cleaning panel BYCQ140D7GW1 - auto cleaning panel BYCQ140D7GW1 - auto cleaning panel BYCQ140D7GW1 - auto cleaning panel BYCQ140D7GW1 - auto cleaning panel BYCQ140D7GW1 - auto cleaning panel
  Colour   Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)
  Dimensions Height mm 130 130 130 130 130 130 130
    Width mm 950 950 950 950 950 950 950
    Depth mm 950 950 950 950 950 950 950
  Weight kg 10.3 10.3 10.3 10.3 10.3 10.3 10.3
Decoration panel 4 Model   BYCQ140D7W1 - white with grey louvers BYCQ140D7W1 - white with grey louvers BYCQ140D7W1 - white with grey louvers BYCQ140D7W1 - white with grey louvers BYCQ140D7W1 - white with grey louvers BYCQ140D7W1 - white with grey louvers BYCQ140D7W1 - white with grey louvers
  Colour   Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)
  Dimensions Height mm 50 50 50 50 50 50 50
    Width mm 950 950 950 950 950 950 950
    Depth mm 950 950 950 950 950 950 950
  Weight kg 5.4 5.4 5.4 5.4 5.4 5.4 5.4
Air filter Type   Resin net Resin net Resin net Resin net Resin net Resin net Resin net
Control systems Infrared remote control   BRC7FA532F BRC7FA532F BRC7FA532F BRC7FA532F BRC7FA532F BRC7FA532F BRC7FA532F
  Wired remote control   BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7 BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7 BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7 BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7 BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7 BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7 BRC1D528, BRC1E53A7, BRC1E53B7, BRC1E53C7
Standard Accessories Operation manual 1 1 1 1 1 1 1
  Installation manual 1 1 1 1 1 1 1
  Drain hose 1 1 1 1 1 1 1
  Clamp for drain hose 1 1 1 1 1 1 1
  Washer for hanger bracket 8 8 8 8 8 8 8
  Screws 4 4 4 4 4 4 4
  Installation guide 2 2 2 2 2 2 2
  Insulation for fitting 2 2 2 2 2 2 2
  Sealing pads 4 4 4 4 4 4 4
  Drain sealing pad 1 1 1 1 1 1 1
  Wire clamp materials 7 7 7 7 7 7 7
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220
Notes (1) - The sound power level is an absolute value indicating the power which a sound source generates. (1) - The sound power level is an absolute value indicating the power which a sound source generates. (1) - The sound power level is an absolute value indicating the power which a sound source generates. (1) - The sound power level is an absolute value indicating the power which a sound source generates. (1) - The sound power level is an absolute value indicating the power which a sound source generates. (1) - The sound power level is an absolute value indicating the power which a sound source generates. (1) - The sound power level is an absolute value indicating the power which a sound source generates.
  (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (2) - The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt.
  (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (3) - BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.
  (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments. (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments. (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments. (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments. (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments. (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments. (4) - This option is intended exclusively for usage in fine dust environments (clothing shops). Do not use this option in high humidity and/or greasy environments.