FCAG71AVEB / AZQS71B2V1B FCAG100AVEB / AZQS100B8V1B FCAG125AVEB / AZQS125B8V1B FCAG140AVEB / AZQS140B8V1B
Indoor unit FCAG71AVEB FCAG100AVEB FCAG125AVEB FCAG140AVEB
Outdoor unit AZQS71BV1 AZQS100B8V1 AZQS125B8V1 AZQS140B8V1
Cooling capacity Nom. kW 6.80 (1) 9.50 (1) 12.1 (1) 13.0 (1)
Heating capacity Nom. kW 7.50 (2) 10.8 (2) 13.5 (2) 15.5 (2)
Power input Cooling Nom. kW 2.19 (3) 2.96 (3) 5.45 (3) 4.94 (3)
  Heating Nom. kW 2.08 (3) 3.09 (3) 3.96 (3) 4.70 (3)
Nominal efficiency EER   3.11 (3) 3.21 (3) 2.22 (3) 2.63 (3)
  COP   3.61 (3) 3.50 (3) 3.41 (3) 3.30 (3)
  Annual energy consumption kWh 1,093 1,480    
  Energy labeling Directive Cooling   B A    
    Heating   A B    
Space cooling Energy efficiency class   A+ A    
  Capacity Pdesign kW 6.80 9.50 12.1 13.0
  SEER   5.70 5.50 5.16 5.94
  ηs,c %     203.5 234.5
  Annual energy consumption kWh/a 418 605 1,406 1,314
  A Condition (35°C - 27/19) Pdc kW 6.80 9.50 12.10 13.00
    EERd   3.31 3.21 2.22 2.63
    Power input kW 2.05 2.96 5.45 4.94
  B Condition (30°C - 27/19) Pdc kW 5.01 7.00 8.92 9.58
    EERd   3.87 4.49 3.90 4.51
    Power input kW 1.29 1.56 2.29 2.12
  C Condition (25°C - 27/19) Pdc kW 3.51 4.56 5.73 6.16
    EERd   7.40 6.29 6.11 7.03
    Power input kW 0.47 0.73 0.94 0.88
  D Condition (20°C - 27/19) Pdc kW 3.63 3.99 4.62 5.75
    EERd   10.16 8.77 9.51 10.88
    Power input kW 0.36 0.46 0.49 0.53
Space heating (Average climate) Energy efficiency class   A+ A    
  Capacity Pdesign kW 6.33 7.60 7.78 11.6
  SCOP/A   4.00 3.85 3.67 3.96
  SCOPnet/A   4.02 3.86 3.67 3.96
  ηs,h %     143.8 155.3
  Annual energy consumption kWh/a 2,216 2,762 2,969 4,089
  Required back up heating cap at design conditions kW 0.580 0.520 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -10 -10
    Pdh (declared heating cap) kW 6.00 7.66 7.78 11.56
    COPd (declared COP)   1.85 2.07 2.34 2.05
    Power input kW 3.24 3.71 3.33 5.64
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -10 -10
    Pdh (declared heating cap) kW 5.60 6.72 7.78 11.56
    COPd (declared COP)   2.25 3.21 2.34 2.05
    Power input kW 2.49 2.10 3.33 5.64
  A Condition (-7°C) Pdh (declared heating cap) kW 5.60 6.72 6.88 10.23
    COPd (declared COP)   2.25 3.21 2.52 2.36
    Power input kW 2.49 2.10 2.73 4.33
  B Condition (2°C) Pdh (declared heating cap) kW 4.06 5.07 4.41 6.27
    COPd (declared COP)   4.05 3.47 3.52 3.91
    Power input kW 1.00 1.47 1.25 1.60
  C Condition (7°C) Pdh (declared heating cap) kW 2.89 3.06 2.84 4.09
    COPd (declared COP)   6.21 5.52 4.71 5.37
    Power input kW 0.47 0.56 0.60 0.76
  D Condition (12°C) Pdh (declared heating cap) kW 3.28 3.49 3.16 4.72
    COPd (declared COP)   7.14 6.51 6.03 6.58
    Power input kW 0.46 0.54 0.52 0.72
Power consumption in other than active mode Crankcase heater mode Cooling PCK kW 0.000 0.000 0.000 0.000
    Heating PCK kW 0.000 0.000 0.012 0.012
  Off mode Cooling POFF kW 0.000 0.007 0.012 0.012
    Heating POFF kW 0.000 0.007 0.012 0.012
  Standby mode Cooling PSB kW 0.007 0.007 0.012 0.012
    Heating PSB kW 0.007 0.007 0.012 0.012
  Thermostat-off mode Cooling PTO kW 0.007 0.007 0.000 0.000
    Heating PTO kW 0.007 0.007 0.012 0.012
Indication if the heater is equipped with a supplementary heater (pair application)     No No
Supplementary heater (pair application) Back-up capacity Heating elbu kW     0.0 0.0
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes
Cold season included No No No No
Warm season included No No No No
Ecolabel logo No No No No
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only