FBA71A2VEB / RZAG71M7Y1B FBA100A2VEB / RZAG71M7Y1B FBA100A2VEB / RZAG100M7Y1B FBA140A2VEB / RZAG100M7Y1B FBA125A2VEB / RZAG125M7Y1B FBA140A2VEB / RZAG140M7Y1B
Indoor unit FBA71A2VEB FBA100A2VEB FBA100A2VEB FBA140A2VEB FBA125A2VEB FBA140A2VEB
Outdoor unit RZAG71M7Y1B RZAG71M7Y1B RZAG100M7Y1B RZAG100M7Y1B RZAG125M7Y1B RZAG140M7Y1B
Cooling capacity Nom. kW 6.80 (1) 6.80 (1) 9.50 (1) 9.50 (1) 12.1 (1) 13.4 (1)
Heating capacity Nom. kW 7.50 (2) 7.50 (2) 10.8 (2) 10.8 (2) 13.5 (2) 15.5 (2)
Space cooling Energy efficiency class   A++ A+ A++ A++    
  Capacity Pdesign kW 6.80 6.80 9.50 9.50 12.1 13.4
  SEER   6.22 5.81 6.47 6.39 6.19 6.42
  ηs,c %         245 254
  Annual energy consumption kWh/a 382 410 514 520 1,173 1,252
  A Condition (35°C - 27/19) Pdc kW 6.80 6.80 9.50 9.50 12.10 13.40
    EERd   3.66 3.93 4.20 4.16 3.33 3.11
    Power input kW 1.86 1.73 2.26 2.28 3.64 4.30
  B Condition (30°C - 27/19) Pdc kW 5.02 5.02 7.00 7.00 8.92 9.88
    EERd   5.60 5.31 5.37 5.51 5.10 5.18
    Power input kW 0.90 0.94 1.30 1.27 1.75 1.91
  C Condition (25°C - 27/19) Pdc kW 3.23 3.23 4.50 4.50 5.74 6.35
    EERd   7.75 7.09 7.67 7.59 6.83 7.28
    Power input kW 0.42 0.46 0.59 0.59 0.84 0.87
  D Condition (20°C - 27/19) Pdc kW 2.89 3.04 4.20 4.40 3.89 4.14
    EERd   9.60 8.34 10.40 9.76 9.87 10.49
    Power input kW 0.30 0.36 0.40 0.45 0.39 0.39
Space heating (Average climate) Energy efficiency class   A+ A+ A+ A+    
  Capacity Pdesign kW 4.70 4.70 7.80 7.80 9.52 9.52
  SCOP/A   4.20 4.06 4.36 4.20 4.12 4.11
  SCOPnet/A   4.20 4.06 4.36 4.20 4.12 4.11
  ηs,h %         162 161
  Annual energy consumption kWh/a 1,566 1,621 2,505 2,600 3,235 3,243
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -10 -10 -10 -10 -10 -10
    Pdh (declared heating cap) kW 4.70 4.70 7.80 7.80 9.52 9.52
    COPd (declared COP)   2.42 2.54 2.28 2.27 1.84 1.95
    Power input kW 1.94 1.85 3.42 3.44 5.17 4.88
  TBivalent Tbiv (bivalent temperature) °C -10 -10 -10 -10 -10 -10
    Pdh (declared heating cap) kW 4.70 4.70 7.80 7.80 9.52 9.52
    COPd (declared COP)   2.42 2.54 2.28 2.27 1.84 1.95
    Power input kW 1.94 1.85 3.42 3.44 5.17 4.88
  A Condition (-7°C) Pdh (declared heating cap) kW 4.16 4.16 6.90 6.90 8.42 8.42
    COPd (declared COP)   2.78 2.90 2.79 2.72 2.33 2.35
    Power input kW 1.50 1.43 2.47 2.54 3.61 3.58
  B Condition (2°C) Pdh (declared heating cap) kW 2.53 2.69 4.20 4.20 5.13 5.13
    COPd (declared COP)   4.31 4.19 4.60 4.47 4.38 4.43
    Power input kW 0.59 0.64 0.91 0.94 1.17 1.16
  C Condition (7°C) Pdh (declared heating cap) kW 2.08 2.24 2.87 2.95 3.55 3.30
    COPd (declared COP)   5.29 4.90 5.09 4.82 5.12 4.94
    Power input kW 0.39 0.46 0.56 0.61 0.69 0.67
  D Condition (12°C) Pdh (declared heating cap) kW 2.46 2.66 3.34 3.42 4.16 3.44
    COPd (declared COP)   6.48 6.09 6.36 5.91 6.45 6.06
    Power input kW 0.38 0.44 0.53 0.58 0.65 0.57
Pto (Thermostat off) W 14, 0 14, 0 14, 0 14, 0    
Power consumption in other than active mode Standby mode Cooling PSB W 14   14      
    Heating PSB W 14   14      
  Crankcase heater mode PCK W 0   0      
  Off mode POFF W 14   14      
Indication if the heater is equipped with a supplementary heater (pair application)         No No
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No
Warm season included No No No No No No
Ecolabel logo No No No No No No
Notes Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Power consumption in other than active mode Standby mode Cooling PSB W   14   14 14 14
    Heating PSB W   14   14 14 14
  Crankcase heater mode PCK W   0   0 0 0
  Off mode POFF W   14   14 14 14
  Thermostat-off mode PTO Heating W         14 14
      Cooling W         0 0