FAA71AUVEB / RZQSG71L3V1B FAA100AUVEB / RZQSG100L9V1B
Cooling capacity Nom. kW 6.80 9.50
  Nom. Btu/h 23,200 32,400
  Nom. kcal/h 5,847 8,169
Heating capacity Nom. kW 7.50 10.80
  Nom. Btu/h 25,600 36,900
  Nom. kcal/h 6,449 9,286
Power input Cooling Nom. kW 2.12 3.16
  Heating Nom. kW 2.08 3.17
Nominal efficiency EER   3.21 3.01
  COP   3.61 3.41
  Annual energy consumption kWh 1,059 1,578
  Energy labeling Directive Cooling   A B
    Heating   A B
Space cooling Energy efficiency class   A+ A+
  Capacity Pdesign kW 6.80 9.50
  SEER   6.05 5.61
  Annual energy consumption kWh/a 394 593
  A Condition (35°C - 27/19) Pdc kW 6.80 9.50
    EERd   3.21 3.01
    Power input kW 2.12 3.16
  B Condition (30°C - 27/19) Pdc kW 5.01 7.00
    EERd   4.17 3.44
    Power input kW 1.20 2.03
  C Condition (25°C - 27/19) Pdc kW 3.65 4.50
    EERd   8.20 7.56
    Power input kW 0.45 0.60
  D Condition (20°C - 27/19) Pdc kW 3.81 3.87
    EERd   11.10 10.39
    Power input kW 0.34 0.37
Space heating (Average climate) Energy efficiency class   A A+
  Capacity Pdesign kW 6.33 6.81
  SCOP/A   3.90 4.01
  SCOPnet/A   4.19 4.02
  Pdh Heating capacity at -10° kW 5.70 6.44
  Annual energy consumption kWh/a 2,123 2,378
  Required back up heating cap at design conditions kW 0.63 0.37
  TOL Tol (temperature operating limit) °C -15 -15
    Pdh (declared heating cap) kW 5.87 7.15
    COPd (declared COP)   1.73 1.79
    Power input kW 3.39 3.99
  TBivalent Tbiv (bivalent temperature) °C -7 -7
    Pdh (declared heating cap) kW 5.60 6.02
    COPd (declared COP)   2.72 2.89
    Power input kW 2.06 2.08
  A Condition (-7°C) Pdh (declared heating cap) kW 5.60 6.02
    COPd (declared COP)   2.72 2.89
    Power input kW 2.06 2.08
  B Condition (2°C) Pdh (declared heating cap) kW 3.46 4.74
    COPd (declared COP)   4.16 3.76
    Power input kW 0.83 1.26
  C Condition (7°C) Pdh (declared heating cap) kW 2.86 2.97
    COPd (declared COP)   5.68 6.13
    Power input kW 0.50 0.48
  D Condition (12°C) Pdh (declared heating cap) kW 3.25 3.38
    COPd (declared COP)   6.58 7.15
    Power input kW 0.49 0.47
Power consumption in other than active mode Crankcase heater mode Cooling PCK kW 0.000 0.000
    Heating PCK kW 0.000 0.000
  Off mode Cooling POFF kW 0.007 0.007
    Heating POFF kW 0.007 0.007
  Standby mode Cooling PSB kW 0.007 0.007
    Heating PSB kW 0.007 0.007
  Thermostat-off mode Cooling PTO kW 0.007 0.007
    Heating PTO kW 0.007 0.007
Cooling Cdc (Degradation cooling)   0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25
Cooling function included Yes Yes
Heating function included Yes Yes
Average climate included Yes Yes
Cold season included No No
Warm season included No No
Eurovent Sound power level outdoor Cooling Nom. dBA 65 70
  Sound power level indoor Cooling Nom. dBA 45 65
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data