EKHBRD016ADV17 / ERRQ016AAV1 EKHBRD011ADV17 / ERRQ011AAV1 EKHBRD014ADV17 / ERRQ014AAV1
Heating capacity Nom. kW 16.0 (1), 16.0 (2), 16.0 (3) 11.3 (1), 11.0 (2), 11.2 (3) 14.5 (1), 14.0 (2), 14.4 (3)
Power input Heating Nom. kW 5.86 (1), 6.65 (2), 4.31 (3) 3.80 (1), 4.40 (2), 2.67 (3) 5.02 (1), 5.65 (2), 3.87 (3)
COP 2.73 (1), 2.41 (2), 3.72 (3) 2.97 (1), 2.50 (2), 4.20 (3) 2.89 (1), 2.48 (2), 3.72 (3)
General Supplier/Manufacturer details Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Name or trademark   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Air-to-water heat pump   Yes Yes Yes
    Brine-to-water heat pump   No No No
    Heat pump combination heater   No No No
    Low-temperature heat pump   No No No
    Supplementary heater integrated   No No No
    Water-to-water heat pump   No No No
  LW(A) Sound power level (according to EN14825) Indoor dB(A) 46.0 59.0 60.0
LW(A) Sound power level (according to EN14825) Outdoor dB(A) 71.0 68.0 69.0
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating general Air to water unit Rated airflow (outdoor) m³/h 6,360 6,360 6,360
  Other Capacity control   Inverter Inverter Inverter
    Cdh (Degradation heating)   1.00 1.00 1.00
    Pck (Crankcase heater mode) kW 0.055 0.055 0.055
    Poff (Off mode) kW 0.055 0.055 0.055
    Psb (Standby mode) kW 0.055 0.055 0.055
    Pto (Thermostat off) kW 0.059 0.059 0.059
  Integrated supplementary heater NOx emission mg/kWh 0.00 0.00 0.00
Space heating Average climate water outlet 55°C General SCOP   3.01    
      Annual energy consumption kWh 10,300    
      Ƞs (Seasonal space heating efficiency) % 117    
      Prated at -10°C kW 15.0    
      Qhe Annual energy consumption (GCV) Gj 37.0    
      Seasonal space heating eff. class   A+    
    A Condition (-7°CDB/-8°CWB) Cdh (Degradation heating)   1.00    
      COPd   2.11    
      Pdh kW 12.1    
      PERd % 84.4    
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.00    
      COPd   3.01    
      Pdh kW 8.54    
      PERd % 120    
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.00    
      COPd   4.26    
      Pdh kW 5.39    
      PERd % 170    
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.940    
      COPd   4.67    
      Pdh kW 4.68    
      PERd % 187    
    Tol (temperature operating limit) COPd   2.01    
      Pdh kW 11.9    
      PERd % 80.4    
      TOL °C -10.0    
      WTOL °C 55.0    
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 3.10    
    Tbiv (bivalent temperature) COPd   2.16    
      Pdh kW 12.6    
      Tbiv °C -6.00    
  Cold climate water outlet 55°C General Annual energy consumption kWh 13,600    
      Ƞs (Seasonal space heating efficiency) % 93.0    
      Prated at -22°C kW 13.7    
      Qhe Annual energy consumption (GCV) Gj 48.9    
  Warm climate water outlet 55°C General Annual energy consumption kWh 6,200    
      Ƞs (Seasonal space heating efficiency) % 114    
      Prated at 2°C kW 13.4    
      Qhe Annual energy consumption (GCV) Gj 22.3    
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.00    
      COPd   2.42    
      Pdh kW 13.4    
      PERd % 96.8    
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.00    
      COPd   3.86    
      Pdh kW 8.44    
      PERd % 154    
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.964    
      COPd   2.89    
      Pdh kW 4.80    
      PERd % 116    
    Tbiv (bivalent temperature) COPd   2.42    
      Pdh kW 13.4    
      PERd % 96.8    
      Tbiv °C 2.00    
  Average climate water outlet 35°C General SCOP   2.88    
      Annual energy consumption kWh 10,800    
      Ƞs (Seasonal space heating efficiency) % 112    
      Prated at -10°C kW 16.0    
      Qhe Annual energy consumption (GCV) Gj 38.8    
      Seasonal space heating eff. class   B    
    A Condition (-7°CDB/-8°CWB) COPd   2.45    
      Pdh kW 12.4    
      PERd % 98.0    
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.00    
      COPd   2.94    
      Pdh kW 8.62    
      PERd % 118    
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.00    
      COPd   3.84    
      Pdh kW 8.03    
      PERd % 154    
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   1.00    
      COPd   4.29    
      Pdh kW 8.05    
      PERd % 172    
    Tol (temperature operating limit) COPd   2.38    
      Pdh kW 12.0    
      PERd % 95.2    
      TOL °C -10.0    
      WTOL °C 35.0    
    Tbiv (bivalent temperature) COPd   2.52    
      Pdh kW 12.6    
      PERd % 101    
      Tbiv °C -5.00    
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 3.99    
  Cold climate water outlet 35°C General Annual energy consumption kWh 13,500    
      Ƞs (Seasonal space heating efficiency) % 97.0    
      Prated at -22°C kW 14.2    
      Qhe Annual energy consumption (GCV) Gj 48.7    
  Warm climate water outlet 35°C General Annual energy consumption kWh 5,410    
      Ƞs (Seasonal space heating efficiency) % 132    
      Prated at 2°C kW 15.9    
      Qhe Annual energy consumption (GCV) Gj 19.5    
Notes EW 55°C; LW 65°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB (1) - EW 55°C; LW 65°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB (1) - EW 55°C; LW 65°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB
  EW 70°C; LW 80°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB (2) - EW 70°C; LW 80°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB (2) - EW 70°C; LW 80°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB
  EW 30°C; LW 35°C; Dt 5°C; ambient conditions: 7°CDB/6°CWB (3) - EW 30°C; LW 35°C; Dt 5°C; ambient conditions: 7°CDB/6°CWB (3) - EW 30°C; LW 35°C; Dt 5°C; ambient conditions: 7°CDB/6°CWB
Space heating Average climate water outlet 55°C General Annual energy consumption kWh   7,320 9,010
      Ƞs (Seasonal space heating efficiency) %   115 116
      Prated at -10°C kW   10.5 13.0
      Qhe Annual energy consumption (GCV) Gj   26.3 32.4
      SCOP     2.96 2.98
      Seasonal space heating eff. class     A+ A+
    A Condition (-7°CDB/-8°CWB) Cdh (Degradation heating)     1.00 1.00
      COPd     2.25 2.15
      Pdh kW   9.36 11.4
      PERd %   90.0 86.0
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)     0.970 1.00
      COPd     3.06 3.02
      Pdh kW   6.22 7.61
      PERd %   122 121
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)     0.950 1.00
      COPd     3.90 3.97
      Pdh kW   4.54 4.53
      PERd %   156 159
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)     0.940 0.940
      COPd     4.67 4.67
      Pdh kW   4.68 4.68
      PERd %   187 187
    Tol (temperature operating limit) COPd     2.02 2.02
      Pdh kW   10.5 11.6
      PERd %   80.8 80.8
      TOL °C   -10.0 -10.0
      WTOL °C   55.0 55.0
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW   0.00 1.40
    Tbiv (bivalent temperature) COPd     2.02 2.15
      Pdh kW   10.5 11.4
      Tbiv °C   -10.0 -7.00
  Cold climate water outlet 55°C General Annual energy consumption kWh   10,200 12,700
      Ƞs (Seasonal space heating efficiency) %   95.0 94.0
      Prated at -22°C kW   10.5 12.9
      Qhe Annual energy consumption (GCV) Gj   36.6 45.6
  Warm climate water outlet 55°C General Annual energy consumption kWh   4,520 5,490
      Ƞs (Seasonal space heating efficiency) %   110 114
      Prated at 2°C kW   9.50 12.1
      Qhe Annual energy consumption (GCV) Gj   16.3 19.8
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)     1.00 1.00
      COPd     2.67 2.56
      Pdh kW   9.54 12.1
      PERd %   107 102
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)     0.968 1.00
      COPd     4.13 4.03
      Pdh kW   7.71 7.55
      PERd %   165 161
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)     0.964 0.964
      COPd     2.89 2.89
      Pdh kW   4.80 4.80
      PERd %   116 116
    Tbiv (bivalent temperature) COPd     2.67 2.49
      Pdh kW   9.54 12.0
      PERd %   107 99.6
      Tbiv °C   2.00 2.00
  Average climate water outlet 35°C General SCOP     2.70 2.81
      Annual energy consumption kWh   7,740 9,590
      Ƞs (Seasonal space heating efficiency) %   105 110
      Prated at -10°C kW   11.0 14.0
      Qhe Annual energy consumption (GCV) Gj   27.9 34.5
      Seasonal space heating eff. class     C B
    A Condition (-7°CDB/-8°CWB) COPd     2.17 2.46
      Pdh kW   9.47 11.5
      PERd %   86.8 98.4
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)     1.00 1.00
      COPd     2.83 2.82
      Pdh kW   6.60 7.54
      PERd %   113 113
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)     1.00 1.00
      COPd     3.84 3.84
      Pdh kW   8.03 8.03
      PERd %   154 154
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)     1.00 1.00
      COPd     4.29 4.29
      Pdh kW   8.05 8.05
      PERd %   172 172
    Tol (temperature operating limit) COPd     2.07 2.39
      Pdh kW   9.58 11.4
      PERd %   82.8 95.6
      TOL °C   -10.0 -10.0
      WTOL °C   35.0 35.0
    Tbiv (bivalent temperature) COPd     2.17 2.54
      Pdh kW   9.47 11.5
      PERd %   86.8 102
      Tbiv °C   -7.00 -5.00
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW   1.42 2.59
  Cold climate water outlet 35°C General Annual energy consumption kWh   10,400 11,900
      Ƞs (Seasonal space heating efficiency) %   93.0 96.0
      Prated at -22°C kW   10.6 12.4
      Qhe Annual energy consumption (GCV) Gj   37.3 42.9
  Warm climate water outlet 35°C General Annual energy consumption kWh   3,900 4,710
      Ƞs (Seasonal space heating efficiency) %   120 130
      Prated at 2°C kW   11.0 13.9
      Qhe Annual energy consumption (GCV) Gj   14.0 16.9