ATXM25N2V1B / ARXM25N2V1B9 ATXM25N2V1B / ARXM25N5V1B9 ATXM35N2V1B / ARXM35N2V1B9 ATXM35N2V1B / ARXM35N5V1B9 ATXM50N2V1B / ARXM50N2V1B9
Indoor unit ATXM25N2V1B ATXM25N2V1B ATXM35N2V1B ATXM35N2V1B ATXM50N2V1B
Outdoor unit ARXM25N2V1B9 ARXM25N5V1B9 ARXM35N2V1B9 ARXM35N5V1B9 ARXM50N2V1B9
Cooling capacity Min. kW 1.30 1.30 1.40 1.40 1.70
  Min. Btu/h 4,400 4,400 4,800 4,800 5,800
  Min. kcal/h 1,118 1,118 1,204 1,204 1,462
  Nom. kW 2.50 2.50 3.40 3.40 5.00
  Nom. Btu/h 8,500 8,500 11,600 11,600 17,100
  Nom. kcal/h 2,150 2,150 2,923 2,923 4,299
  Max. kW 3.20 3.20 4.00 4.00 6.00
  Max. Btu/h 10,900 10,900 13,600 13,600 20,500
  Max. kcal/h 2,752 2,752 3,439 3,439 5,159
Heating capacity Min. kW 1.30 1.30 1.40 1.40 1.70
  Min. Btu/h 4,400 4,400 4,800 4,800 5,800
  Min. kcal/h 1,100 1,100 1,200 1,200 1,500
  Nom. kW 2.80 2.80 4.00 4.00 5.80
  Nom. Btu/h 9,600 9,600 13,600 13,600 19,800
  Nom. kcal/h 2,408 2,408 3,439 3,439 4,987
  Max. kW 4.70 4.70 5.20 5.20 7.70
  Max. Btu/h 16,000 16,000 17,700 17,700 26,300
  Max. kcal/h 4,041 4,041 4,471 4,471 6,621
Power input Cooling Nom. kW 0.57 0.57 0.83 0.83 1.45
  Heating Nom. kW 0.56 0.56 0.99 0.99 1.53
Nominal efficiency EER   4.39 4.39 4.09 4.09 3.45
  COP   5.00 5.00 4.04 4.04 3.79
  Annual energy consumption kWh 285 285 416 416 725
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Space cooling Capacity Pdesign kW 2.50 2.50 3.40 3.40 5.00
  Energy efficiency class   A+++ A+++ A+++ A+++ A++
  SEER   8.55 8.55 8.55 8.55 7.35
  Annual energy consumption kWh/a 102 102 139 139 238
  A Condition (35°C - 27/19) Pdc kW 2.50 2.50 3.40 3.40 5.00
    EERd   4.39 4.39 4.09 4.09 3.45
    Power input kW 0.57 0.57 0.83 0.83 1.45
  B Condition (30°C - 27/19) Pdc kW 1.84 1.84 2.51 2.51 3.68
    EERd   6.53 6.53 6.19 6.19 5.55
    Power input kW 0.28 0.28 0.41 0.41 0.66
  C Condition (25°C - 27/19) Pdc kW 1.18 1.18 1.55 1.55 2.37
    EERd   9.93 9.93 10.10 10.10 8.29
    Power input kW 0.12 0.12 0.15 0.15 0.29
  D Condition (20°C - 27/19) Pdc kW 1.05 1.05 1.07 1.07 1.83
    EERd   16.20 16.20 16.24 16.24 14.55
    Power input kW 0.06 0.06 0.07 0.07 0.13
Space heating (Average climate) Capacity Pdesign kW 2.40 2.40 2.50 2.50 4.60
  Energy efficiency class   A+++ A+++ A+++ A+++ A++
  SCOP/A   5.10 5.10 5.10 5.10 4.65
  SCOPnet/A   5.14 5.14 5.14 5.14 4.69
  Pdh Heating capacity at -10° kW 2.30 2.30 2.35 2.35 4.09
  Annual energy consumption kWh/a 659 659 687 687 1,384
  Required back up heating cap at design conditions kW 0.10 0.1 0.15 0.15 0.51
  TOL Tol (temperature operating limit) °C -20 -20 -20 -20 -20
    Pdh (declared heating cap) kW 2.14 2.14 2.14 2.14 3.12
    COPd (declared COP)   2.29 2.29 2.49 2.49 2.06
    Power input kW 0.93 0.93 0.86 0.86 1.51
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 2.12 2.12 2.21 2.21 4.07
    COPd (declared COP)   3.60 3.60 3.50 3.50 2.85
    Power input kW 0.59 0.59 0.63 0.63 1.43
  A Condition (-7°C) Pdh (declared heating cap) kW 2.12 2.12 2.21 2.21 4.07
    COPd (declared COP)   3.60 3.60 3.50 3.50 2.85
    Power input kW 0.59 0.59 0.63 0.63 1.43
  B Condition (2°C) Pdh (declared heating cap) kW 1.29 1.29 1.34 1.34 2.48
    COPd (declared COP)   5.13 5.13 5.13 5.13 4.61
    Power input kW 0.25 0.25 0.26 0.26 0.54
  C Condition (7°C) Pdh (declared heating cap) kW 0.94 0.94 0.95 0.95 1.61
    COPd (declared COP)   6.22 6.22 6.22 6.22 6.41
    Power input kW 0.15 0.15 0.15 0.15 0.25
  D Condition (12°C) Pdh (declared heating cap) kW 0.98 0.98 1.09 1.09 1.80
    COPd (declared COP)   7.81 7.81 7.81 7.81 7.13
    Power input kW 0.12 0.12 0.14 0.14 0.25
Space heating (Warm climate) Capacity Pdesignh kW 1.29 1.29 1.35 1.35 2.48
  Energy efficiency class   A+++ A+++ A+++ A+++ A+++
  SCOP   6.15 6.15 6.14 6.14 5.97
  SCOPnet   6.26 6.26 6.30 6.30 6.08
  Annual energy consumption kWh/a 294 294 305 305 581
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -20 -20 -20 -20 -20
    Pdh (declared heating cap) kW 2.14 2.14 2.59 2.59 3.12
    COPd (declared COP)   2.29 2.29 2.49 2.49 2.06
    Power input kW 0.93 0.93 1.04 1.04 1.51
  TBivalent Tbiv (bivalent temperature) °C 2 2 2 2 2
    Pdh (declared heating cap) kW 1.29 1.29 1.34 1.34 2.48
    COPd (declared COP)   5.13 5.13 5.13 5.13 4.61
    Power input kW 0.25 0.25 0.26 0.26 0.54
  B Condition (2°C) Pdh (declared heating cap) kW 1.29 1.29 1.34 1.34 2.48
    COPd (declared COP)   5.13 5.13 5.13 5.13 4.61
    Power input kW 0.25 0.25 0.26 0.26 0.54
  C Condition (7°C) Pdh (declared heating cap) kW 0.94 0.94 0.95 0.95 1.61
    COPd (declared COP)   6.22 6.22 6.22 6.22 6.41
    Power input kW 0.15 0.15 0.15 0.15 0.25
  D Condition (12°C) Pdh (declared heating cap) kW 0.98 0.98 1.09 1.09 1.80
    COPd (declared COP)   7.81 7.81 7.81 7.81 7.13
    Power input kW 0.12 0.12 0.14 0.14 0.25
Power consumption in other than active mode Crankcase heater mode PCK W 0 0 0 0 0
  Off mode POFF W 1 1 1 1 1
  Standby mode Cooling PSB W 1 1 1 1 1
    Heating PSB W 1 1 1 1 1
  Thermostat-off mode PTO Cooling W 6 6 6 6 12
      Heating W 7 7 7 7 13
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes
Cold season included No No No No No
Warm season included Yes Yes Yes Yes Yes
Ecolabel logo No No No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 58 58 61 61 62
  Sound power level indoor Cooling Nom. dBA 58 58 58 58 58
  Piping length Cooling Measuring condition m 5.00 5.00 5.00 5.00 5.00
Power factor Nominal Cooling % 93.90 (0.000) 93.90 (0.000) 79.90 (0.000) 79.90 (0.000) 95.00 (0.000)
    Heating % 98.20 (0.000) 98.20 (0.000) 90.00 (0.000) 90.00 (0.000) 96.10 (0.000)
Current Nominal running current (RLA) - 50Hz Cooling A 2.60 2.60 4.50 4.50 6.64
    Heating A 2.50 2.50 4.80 4.80 6.92
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.