ADEA35A2VEB / ARXM35N5V1B9 ADEA35A2VEB / ARXM35N2V1B9 ADEA50A2VEB / ARXM50N2V1B9 ADEA60A2VEB / ARXM60N2V1B9 ADEA71A2VEB / ARXM71N2V1B9
Indoor unit ADEA35A2VEB ADEA35A2VEB ADEA50A2VEB ADEA60A2VEB  
Outdoor unit ARXM35N5V1B9 ARXM35N2V1B9 ARXM50N2V1B9 ARXM60N2V1B9  
Cooling capacity Nom. kW 3.40 3.40 5.00 5.70 6.80
  Nom. Btu/h 11,600 11,600 17,100 19,400 23,200
  Nom. kcal/h 2,923 2,923 4,299 4,901 5,847
  Max. kW         6.98
  Max. Btu/h         23,800
  Max. kcal/h         6,002
Heating capacity Nom. kW 4.00 4.00 5.50 7.00 7.50
  Nom. Btu/h 13,600 13,600 18,800 23,900 25,600
  Nom. kcal/h 3,439 3,439 4,729 6,019 6,449
  Max. kW         7.66
  Max. Btu/h         26,100
  Max. kcal/h         6,586
Power input Cooling Nom. kW 0.90 0.90 1.53 1.66 2.31
  Heating Nom. kW 1.01 1.01 1.47 1.93 2.15
Nominal efficiency EER   3.76 3.76 3.27 3.43 2.95
  COP   3.97 3.97 3.74 3.63 3.49
  Annual energy consumption kWh 452 452 765 831 1,153
  Energy labeling Directive Cooling   A A A A C
    Heating   A A A A B
Space cooling Capacity Pdesign kW 3.40 3.40 5.00 5.70 6.80
  Energy efficiency class   A+ A+ A+ A+ A
  SEER   5.75 5.75 5.65 5.74 5.35
  Annual energy consumption kWh/a 207 207 310 347 445
  A Condition (35°C - 27/19) Pdc kW 3.40 3.40 5.00 5.70 6.80
    EERd   3.76 3.76 3.27 3.43 2.95
    Power input kW 0.90 0.90 1.53 1.66 2.31
  B Condition (30°C - 27/19) Pdc kW 2.51 2.51 3.64 4.20 5.01
    EERd   5.06 5.06 4.64 4.86 4.23
    Power input kW 0.50 0.50 0.78 0.86 1.18
  C Condition (25°C - 27/19) Pdc kW 1.73 1.73 2.36 2.70 3.22
    EERd   7.43 7.43 7.31 7.48 7.05
    Power input kW 0.23 0.23 0.32 0.36 0.46
  D Condition (20°C - 27/19) Pdc kW 1.61 1.61 1.98 2.13 1.87
    EERd   8.29 8.29 9.17 8.24 7.55
    Power input kW 0.19 0.19 0.22 0.26 0.25
Space heating (Average climate) Capacity Pdesign kW 2.90 2.90 4.40 4.60 6.00
  Energy efficiency class   A+ A+ A+ A+ A
  SCOP/A   4.00 4.00 4.00 4.00 3.80
  SCOPnet/A   4.03 4.03 4.04 4.03 3.83
  Pdh Heating capacity at -10° kW 2.41 2.41 3.73 4.00 4.83
  Annual energy consumption kWh/a 1,014 1,014 1,538 1,610 2,209
  Required back up heating cap at design conditions kW 0.49 0.49 0.67 0.60 1.17
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 2.15 2.15 3.47 3.85 4.03
    COPd (declared COP)   2.37 2.37 1.95 2.11 1.71
    Power input kW 0.91 0.91 1.78 1.82 2.36
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 2.57 2.57 3.89 4.09 5.31
    COPd (declared COP)   2.73 2.73 3.09 3.01 2.27
    Power input kW 0.94 0.94 1.26 1.36 2.34
  A Condition (-7°C) Pdh (declared heating cap) kW 2.57 2.57 3.89 4.09 5.31
    COPd (declared COP)   2.73 2.73 3.09 3.01 2.27
    Power input kW 0.94 0.94 1.26 1.36 2.34
  B Condition (2°C) Pdh (declared heating cap) kW 1.57 1.57 2.37 2.44 3.23
    COPd (declared COP)   3.89 3.89 4.20 4.18 3.93
    Power input kW 0.40 0.40 0.56 0.58 0.82
  C Condition (7°C) Pdh (declared heating cap) kW 1.02 1.02 1.61 1.60 2.08
    COPd (declared COP)   5.18 5.18 4.34 4.41 5.00
    Power input kW 0.20 0.20 0.37 0.36 0.42
  D Condition (12°C) Pdh (declared heating cap) kW 1.19 1.19 1.58 1.79 1.58
    COPd (declared COP)   6.38 6.38 5.23 5.32 5.10
    Power input kW 0.19 0.19 0.30 0.34 0.31
Space heating (Warm climate) Capacity Pdesignh kW 1.57 1.57 2.37 2.44 3.23
  Energy efficiency class   A+++ A+++ A+ A+ A++
  SCOP   5.11 5.11 4.33 4.37 4.63
  SCOPnet   5.18 5.18 4.40 4.44 4.69
  Annual energy consumption kWh/a 430 430 766 782 977
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 2.15 2.15 3.47 3.85 4.03
    COPd (declared COP)   2.37 2.37 1.95 2.11 1.71
    Power input kW 0.91 0.91 1.78 1.82 2.36
  TBivalent Tbiv (bivalent temperature) °C 2 2 2 2 2
    Pdh (declared heating cap) kW 1.57 1.57 2.37 2.44 3.23
    COPd (declared COP)   3.89 3.89 4.20 4.18 3.93
    Power input kW 0.40 0.40 0.56 0.58 0.82
  B Condition (2°C) Pdh (declared heating cap) kW 1.57 1.57 2.37 2.44 3.23
    COPd (declared COP)   3.89 3.89 4.20 4.18 3.93
    Power input kW 0.40 0.40 0.56 0.58 0.82
  C Condition (7°C) Pdh (declared heating cap) kW 1.02 1.02 1.61 1.60 2.08
    COPd (declared COP)   5.18 5.18 4.34 4.41 5.00
    Power input kW 0.20 0.20 0.37 0.36 0.42
  D Condition (12°C) Pdh (declared heating cap) kW 1.19 1.19 1.58 1.79 1.58
    COPd (declared COP)   6.38 6.38 5.23 5.32 5.10
    Power input kW 0.19 0.19 0.30 0.34 0.31
Power consumption in other than active mode Crankcase heater mode PCK W 0 0 0 0 0
  Off mode POFF W 7 7 10 10 10
  Standby mode Cooling PSB W 7 7 10 10 10
    Heating PSB W 7 7 9 9 9
  Thermostat-off mode PTO Cooling W 7 7 13 13 13
      Heating W 7 7 17 17 17
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes
Cold season included No No No No No
Warm season included Yes Yes Yes Yes Yes
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61 62 63 65
  Sound power level indoor Cooling Nom. dBA 60 60 60 56 56
  Piping length Cooling Measuring condition m 5 5 5 5 5
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.